Handheld Potentiostat, Electrochemical Analyzer (MedPstat 1.0 Advance -100mA)

$1,299.00

  • Handheld, Portable, Most Affordable & Highly Precise Potentiostat
  • Applied Potential Range: ±2.4 V
  • Max Current Range: 100 mA
  • USB Communication
  • Software for PC Data acquisition & plotting

MedPstat 1.0 Advance is the most cost-effective Electrochemical Analyzer, Handheld / Portable, Affordable, and precise Potentiostat, with a wide range of ±2.4 V, 100 mA. It is optimal for electrochemistry learning and the best for any electrochemistry research applications. It comes with high-quality dummy cells for learning/calibration applications and software for PC data acquisition and plotting.

Detailed Specifications:

  • Electrochemical Methods: CV, LSV, ChronoAmp, OCP, DPV, SWV
  • Channels Per Unit: 1
  • Applied potential range: ±2.4 V
  • Applied Potential Accuracy: 0.1% of the setpoint, 1mV Max
  • Applied Potential Resolution: 76 µV
  • Measured Potential Accuracy: 0.1% of the setpoint, 1mV Max
  • Measured Potential Resolution: 156 µV
  • Compliance Voltage: ±8 V
  • Maximum Current: 100 mA
  • Current ranges: 7 Ranges
  • Measured Current Accuracy: 0.5% of the range, 50pA max
  • Measured Current Resolution: 0.015% of range, 1.5 pA
  • Input Impedance: >10 TΩ
  • Input Bias Current: 1pA Max
  • Computer Interface: USB
  • Channel Cable Length: 0.8 meters
  • Power supply: 12V DC
  • Power Supply Requirements: 100V - 240V AC
  • Weight: 285 grams
  • Physical Dimensions: 181mm * 91.5mm * 42mm
  • Operating temperature range: 0 to 50°C
  • Communication: USB
  • PC Software: Available with a lifetime license
  • Bandwidth: up to 4 MHz
  • Max. data acquisition rate: 1 KHz
  • ADC/DAC Resolution: 16 bit
  • Slew Rate (No Load): 3.5 V/µs
  • Maximum ADC Sampling Speed: 5,00,000 samples/sec

Additional information

Weight 1.4 kg
Dimensions 340 × 300 × 90 cm
Select Model

MedPstat 1.0 (Basic) 30mA, MedPstat 1.0 (Advance) 100mA, MedPstat 1.0 (EC Kit) with Cell Setup

MedPstat 1.0 Advance proudly featured in the Latest Publication by IIT-K

The MedPstat 1.0 Advance potentiostat is extremely lightweight & high in precision and was selected for Microbial Fuel Cell Research by the Department of Materials Science and Engineering, Indian Institute of Technology Kanpur, India.

Since then it has been a huge part of the scientific community and has been utilized for testing and research by many other Universities! 

Read more >

The MedPStat 1.0 Advance was featured in Y. Budania, M. Chauhan, S. Mishra, S. Singh, Chemical Engineering Journal (2024) 156018. 

Key Electrochemistry characterizations were tested and performed in this publication! Read all about it!

Software

MedPstat comes with lifetime free licensed version of MedEplot data acquisition & plotting software. It is compatible with any PC or laptop with windows OS.

Simple User Interface

Light Weight Software

Live Data View

Save Data in CSV

Open / Overlay Plot

Windows / IOs

MedPstat Models

Most Versatile Potentiostat

  • Applied Potential Range: ±2.4 V

  • Max Current Range: 100 mA

  • Current Resolution: 1.5 pA

  • Mini Dummy Cell

  • Warranty: 1 Year

MedPstat Models Comparison

Video Tutorial

Application Notes

MedPstat Research Publications

Chemical Engineering Journal (Impact Factor: 16.5)

N/NiO-ornated graphitic fiber-engrained micro-carbon beads: Innovative packed bed type capacitive electrodes for microbial fuel cells

The potentiostat (Autolab-M204, Metrohm, Netherlands and MedPstat 1.0 Advance, MTX Labs, India) was used for electrochemical anal ysis, and a modified version of an earlier protocol was followed [5,8].

DOI: https://doi.org/10.1016/j.cej.2024.156018

 ____________________________________________________________________________________________________________________

ROYAL SOCIETY OF CHEMISTRY (Impact Factor: 7.92)

CVD-Grown NiO-Carbon Nanofiber Decorated rGO Hybrids for High-Performance Electrochemical Hydrogen Storage: Role of Hierarchical Porous Structures

All electrochemical analyses were carried out using a computer-controlled potentiostat (Autolab-M204, Metrohm, Netherlands and MedPstat 1.0 Advance, MTX Labs, India), with data acquisition and processing through NOVA 2.0 software.

DOI: https://doi.org/10.1039/D5NR02443A

 ____________________________________________________________________________________________________________________

Journal of the Indian Chemical Society (Impact Factor: 3.4)

Tailoring the electrochemical properties of Ni-doped Co3O4 for Advanced supercapacitor electrodes

The MTX MedPStat 2.0 (MTX  Industries, India) was used to conduct cyclic voltammetry (CV), galva nostatic charge–discharge (GCD), and Cyclic stability experiments over a potential window of 0.1 to 0.6 V

DOI: https://doi.org/10.1016/j.jics.2025.102170

Read More…

FAQs