Welcome to this comprehensive application note, crafted to offer detailed guidance on utilizing the Dummy cell for potentiostat calibration, specifically focusing on the Linear Sweep Voltammetry (LSV) technique. This document aims to equip you with the necessary...
Handheld Potentiostat/Galvanostat, Electrochemical Analyzer (MedPstat 2.0 Advance)
Original price was: $3,100.00.$2,990.00Current price is: $2,990.00.
- Handheld Affordable & Potentiostat/Galvanostat
- Applied Potential Range: ± 10 V
- Max Current Range: 250 mA
- Measured Potential Range (Gal): ±10 V
- USB Communication
- Software for PC Data acquisition & plotting
MedPstat 2.0 Advance is a Portable, Affordable, & Precision Potentiostat/Galvanostat with a wide range of ± 10V, 250 mA. Optimum for electrochemistry research applications. Included is a high-quality dummy cell for learning & calibration applications and lifetime access to free software - MedEplot for PC, data acquisition & plotting.
Detailed Specifications:
- Electrochemical Methods: CV, LSV, ChronoAmp, OCP, DPV, SWV, ChronoPot, Charge-Discharge, Corrosion Analysis (Tafel), Corrosion Analysis (Polarization Resistances)
- Channels Per Unit: 1
- Applied potential range: ± 10 V
- Applied Potential Accuracy: 0.1% of the setpoint, 1mV Max
- Applied Potential Resolution: 345 µV
- Measured Potential Accuracy: 0.1% of the setpoint, 1mV Max
- Measured Potential Resolution: 312 µV
- Compliance Voltage: ±15 V
- Maximum Current: 250 mA
- Current ranges: 7 Ranges (10nA to 250mA)
- Measured Current Accuracy: 1% of the range, 100pA max
- Measured Current Resolution: 0.03% of range, 3 pA
- Applied Current Resolution (Gal): 3.45 nA
- Measured Potential Range (Gal): ±10 V
- Input Impedance: > 10 TΩ
- Input Bias Current: 1pA Max
- Computer Interface: USB
- Channel Cable Length: 0.8 meters
- power supply: 24V DC
- Power Supply Requirements: 100V - 240V AC
- Weight: 320 grams
- Physical Dimensions: 181mm * 91.5mm * 42mm
- Operating temperature range: 0 to 50°C
- Communication: USB
- PC Software: Available with a lifetime license
- Bandwidth: up to 10 MHz
- Max. data acquisition rate: 1 KHz
- ADC/DAC Resolution: 16 bit
- Slew Rate (No Load): 45V/µs
- Maximum ADC Sampling Speed: 5,00,000 samples/sec
Additional information
| Weight | 1.4 kg |
|---|---|
| Dimensions | 340 × 300 × 90 cm |
| Select Model | MedPstat 1.0 (Basic) 30mA, MedPstat 1.0 (Advance) 100mA, MedPstat 1.0 (EC Kit) with Cell Setup |
Software
MedPstat comes with lifetime free licensed version of MedEplot data acquisition & plotting software. It is compatible with any PC or laptop with windows OS.
MedEplot is specifically designed to
Simple User Interface
Light Weight Software
Live Data View
Save Data in CSV
Open / Overlay Plot
Windows / IOs
MedPstat 2.0 Advance Kit Package
Most Versatile Potentiostat/Galvanostat (1 piece)
Electrode Cable (1 Piece)
Mini Dummy Cell (1 piece)
Power Adaptor (1 piece)
USB C Cable (1 piece)
Pen Drive with Software (1 piece)
Warranty: 1 Year
Offer Price: $2990
MedPstat Models Comparison
Videos
Application Notes
A Comprehensive Guide to conduct Cyclic Voltammetry with MedPstat 1.0 Instrument:
This application note provides a comprehensive manual for using the MedPstat device in Ferro/Ferri cyanide redox couple investigations. This Ferro/Ferri cyanide redox system is an excellent model for understanding cyclic voltammetry and electrochemical processes....
MedPstat Research Publications
Chemical Engineering Journal (Impact Factor: 16.5)
N/NiO-ornated graphitic fiber-engrained micro-carbon beads: Innovative packed bed type capacitive electrodes for microbial fuel cells
The potentiostat (Autolab-M204, Metrohm, Netherlands and MedPstat 1.0 Advance, MTX Labs, India) was used for electrochemical anal ysis, and a modified version of an earlier protocol was followed [5,8].
DOI: https://doi.org/10.1016/j.cej.2024.156018
____________________________________________________________________________________________________________________
ROYAL SOCIETY OF CHEMISTRY (Impact Factor: 7.92)
CVD-Grown NiO-Carbon Nanofiber Decorated rGO Hybrids for High-Performance Electrochemical Hydrogen Storage: Role of Hierarchical Porous Structures
All electrochemical analyses were carried out using a computer-controlled potentiostat (Autolab-M204, Metrohm, Netherlands and MedPstat 1.0 Advance, MTX Labs, India), with data acquisition and processing through NOVA 2.0 software.
DOI: https://doi.org/10.1039/D5NR02443A
____________________________________________________________________________________________________________________
Journal of the Indian Chemical Society (Impact Factor: 3.4)
Tailoring the electrochemical properties of Ni-doped Co3O4 for Advanced supercapacitor electrodes
The MTX MedPStat 2.0 (MTX Industries, India) was used to conduct cyclic voltammetry (CV), galva nostatic charge–discharge (GCD), and Cyclic stability experiments over a potential window of 0.1 to 0.6 V
DOI: https://doi.org/10.1016/j.jics.2025.102170